PESTS PROTECTED CABLES: A STRATEGY FOR EFFECTIVE PREVENTION OF FIRE OUTBREAK FROM ELECTRICAL INSTALLATIONS IN WORKSHOPS IN TECHNICAL COLLEGES IN RIVERS STATE
Abstract
This study on pests protected cables as a strategy for effective prevention of fire outbreak from electrical installations in workshops in technical colleges in Rivers State was necessitated by the frequent fire outbreak from electrical installation in workshops in technical colleges. A research question and two null hypotheses guided the study. A descriptive survey research design was employed for the study. The population for this study comprised of 45 electrical teachers in four technical colleges in Rivers State. The entire population was studied without sampling since the size was not too large and was manageable. The instrument for data collection was a structured questionnaire titledPest Protected Cables for Effective Prevention of Fire Outbreak from Electrical Installation in Workshops.The instrument was validated by two experts from the Departments of Industrial Technical Education and Educational Foundations in Ignatius Ajuru University of Education, Port Harcourt. Using the Cronbach alpha method to determine the reliability of the instrument, the reliability co-efficient of 0.78 was obtained. The data collected for the study were analyzed using mean and standard deviation to answer the research questions and to determine the closeness of the respondents mean ratings. The t-test was used to test the null hypotheses at 0.05 level of significance. The findings of study revealed that pests protected cables will be very effective strategy for prevention of fire outbreak from electrical installations in workshops in technical colleges. The findings also showed that year of experience and location had no significant influence on the opinion of respondents on the effective of peste protected cables as a strategy for prevention of fire outbreak from electrical installations in workshops in technical colleges. Based on the findings of this study, it was recommended that pests protected cables should be used during construction and renovation of workshops among others.
Keywords. Pest protected cables, technical colleges, workshop, fire outbreak.
Keywords
Full Text:
PDFReferences
Abel, F. (2019). National Electrical Code. National Electrical Manufacturers Association Press.
Akin, G. (2016). New Cable Colour Code for Electrical Installations. Energy Market
Authority Press
Akpan, R.M. (2015). Color Coding Chart.Wisdom Publishers.
Dan, C. (2017). Towards Universal Energy Access by 2030: Areas requiring further
research, Presentation to the Center for Science and Technology Policy Research.
Danga, A. (2022). Processing of wire from antiquity to the future. Wire Journal International.
(2),5866.
Eaton, T.P. (2016). Experimentally Defined Convolutional Neural Network Architecture
Variants for Non-temporal Real-time Fire Detection. Proc. International Conference on
Image Processing (PDF). IEEE. Retrieved 9 August 2018Ethan, H.N. (2015). The
Metallurgy of Copper Wire Archived. litz-wire.com
Ezeji, E.K. (2014). Aluminum Building Wire Installation and Terminations. IAEI Net
Hugh, A. (2014). Non-temporal Texture Driven Approach to Real-time Fire Detection. Proc.
International Conference on Image Processing (PDF). IEEE. pp. 17811784. doi?:?
1109/ICIP.2011.6115796?. hdl:1826/7588.
James, F.K. (2016). Fundamental Fire Protection Program andDesign Elements. National Fire
Protection Association.
Keystone, G. (2020). Energy Poverty and Development in Papua New Guinea: Learning from
the Teacher's Solar Association Lighting Project. Forum for Development Studies 40(2)
-349.
University of Illinois Extension, (2013). Tree Squirrels Damage Prevention and Control Measures Living with Wildlife in Illinois. University of Illinois Board of Trustees.
Refbacks
- There are currently no refbacks.
Copyright © 2018-2024. NAU Journal of Technology & Vocational Education (NAU JTVED). All Rights Reserved. ISSN: 2449-1764
Powered by Myrasoft Systems Ltd.(Website: http://www.myrasoft.com.ng )